Free tool · Canadian Electrical Code, BC

Can my panel handle an EV charger?

Enter your home's details and get a load estimate in seconds — the same Rule 8-200 calculation an electrician runs before quoting a panel upgrade, an EV charger, a hot tub or a heat pump.

Example values are loaded so you can see how it works. Replace them with your own — use the nameplate watts from the equipment labels. Enter 0 for anything you don't have.

Your home

Main + upper floors.
Counts at 75%.
The number on your main breaker.
0 if you heat with gas. Add up all electric heaters / baseboards.
0 if none.
0 if gas or none. A second range or wall oven goes under "other loads" below.
0 if none. A hot tub goes here. A storage tank water heater goes under "other loads".
0 if none. About 7,200 W for a 30 A charger, 9,600 W for 40 A. Use the charger's max setting. A second charger goes here too.
Clothes dryer, electric storage water heater, wall oven, sauna, kiln — only ones over 1,500 W. Add their nameplate watts together. Any other fixed load you're adding goes here.

Your estimate

Basic area load (lights & plugs)—
Heating / A/C —
Electric range—
Tankless / pool / spa / hot tub—
EV charger—
Other large loads—
Itemized total—
Code minimum (Rule 8-200(1)(b))—
Governing load—

Adding to an existing service? Your BC Hydro history can sometimes show room the standard calculation doesn't (Rule 8-106(8)). Here's how to download your 12-month hourly meter data — send us the file and we'll check it. It's often the difference between an upgrade and no upgrade.

Running the new load a long way — detached garage, back of the yard? Check the voltage drop too: a long run can need a bigger wire even when the service has room.

More free tools: all our calculators and useful links in one place.

How the numbers work

  1. Area load: 5,000 W for the first 90 m² of living area, plus 1,000 W per additional 90 m² or part. Basement counts at 75%.
  2. Heating: 100% of the first 10 kW, 75% of the rest. A/C counts at 100% — if the two are interlocked so they can't run together, only the larger counts.
  3. Range: 6,000 W for a range rated up to 12 kW, plus 40% of anything over 12 kW.
  4. EV charger, tankless heater, pool/spa/hot tub: 100% — no demand break.
  5. Other large loads: 25% each when an electric range is present; otherwise 100% of the first 6,000 W combined, then 25% of the rest.
  6. Minimum: the result can't be less than 24,000 W (100 A) for a home of 80 m² or more above the basement, or 14,400 W (60 A) for a smaller one.

Please read this before relying on the result

This calculator gives a screening estimate only, using the demand factors in Rule 8-200(1) of the Canadian Electrical Code as adopted in BC (2024 edition). It is not a substitute for a load calculation by a qualified person, and it doesn't replace an electrical permit or inspection.

Real installations depend on nameplate ratings, the condition of existing wiring, and details this tool can't see. Figures may contain errors. Harbour Electrical Services Ltd. isn't liable for decisions made from these results. If the numbers are close, or before you buy equipment, get the calculation checked properly — that's a free conversation, not a commitment.

Want the real answer for your home?

Send us your panel photo and what you're adding — EV charger, hot tub, heat pump, suite — and we'll check the calculation and tell you straight whether your service can carry it, or what an upgrade would take. No obligation.